ÜRÜNLER
- Yangına Dayanıklı Kablolar
M2X
Used as fixed installation cable in marine vehicles. Halogen-Free and Flame Retardant construction ensures non-corrosive and highly visible environment during a fire.
- Conductor Stranded Annealed Copper (IEC/EN 60228, Class 5) (tinned copper and/or Class 2 versions are available upon request)
- Insulation XL HFFR (IEC 60092-360 HF90), Standard Outer Sheath: Black (other colors and double sheath upon request)
- Reference Standards IEC 60092-353
- Operating Voltage 0.6/1 (1.2) kV
- Test Voltage 3.5 kV (a.c.) 8.4 kV (d.c)
- Conductor Resistance IEC/EN 60228
- Insulation Resistance >4000 M.Ω x km
- Temperature Range -40 °C........+90 °C
- Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
- Smoke Density IEC/EN 61034-1+2
- Amount of Halogen Acid Gas IEC/EN 60754-1
- Corrosive Gases Measurement IEC/EN 60754-2
- Min. Bending Radius (Fixed) 4 x Cable Diameter