ÜRÜNLER
- Yangına Dayanıklı Kablolar
FM2XASH
Used for communication and instrumentation purpose in electronic systems of marine vehicles. Screening layer protects the transmitting signal against electromagnetic interferences. Halogen-Free and Flame Retardant construction ensure non-corrosive and highly visible environment during a fire.
- Conductor Stranded Annealed Copper (IEC/EN 60228, Class 2) (tinned copper and/or Class 5 versions are available upon request)
- Insulation XLPE (IEC 60092-360)
- Core Colors Pair: Black / White, Numbered Quad: Black / White / Red / Blue, Numbered
- Lay-up Cores / pairs / triples / quads are stranded in layers
- Separator PET Foil
- Overall Screen Al-PET Foil (with Tinned Copper Drain Wire)
- Inner Sheath HFFR
- Armour Galvanised Steel Wire Braid
- Outer Sheath HFFR (IEC 60092-360 SHF1), RAL 9005 - Black or RAL 7001 - Grey
- Reference Standards IEC 60092-376
- Operating Voltage 150/250 (300) V
- Test Voltage 1.5 kV (a.c) 3.6 kV (d.c)
- Conductor Resistance IEC/EN 60228
- Insulation Resistance >5000 M.Ωxkm
- Temperature Range -40 °C........+90 °C
- Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
- Smoke Density IEC/EN 61034-1+2
- Amount of Halogen Acid Gas IEC/EN 60754-1
- Corrosive Gases Measurement IEC/EN 60754-2
- Min. Bending Radius (Fixed) 8 x Cable Diameter