            FM2XAASH FE180
Used for communication and instrumentation purpose in electronic systems of marine vehicles. Screening layer protects the transmitting signal against electromagnetic interferences. Halogen-Free and Flame Retardant construction ensure non-corrosive and highly visible environment during a fire. Also, min.180 minutes of circuit integrity under fire conditions is achieved by its special design.
- Conductor Stranded Annealed Copper (IEC/EN 60228, Class 2) (tinned copper and/or Class 5 versions are available upon request)
 - Flame Barrier Mica Tape
 - Insulation XLPE (IEC 60092-360)
 - Core Colors Pair: Black / White, Numbered Quad: Black / White / Red / Blue, Numbered
 - 1. Separator PET Foil
 - Individual Screen Al-PET Foil (with Tinned Copper Drain Wire)
 - 2. Separator PET Foil
 - Lay-up Shielded pairs / triples are stranded in layers
 - Separator PET Foil
 - 1. Overall Screen Al-PET Foil (with Tinned Copper Drain Wire)
 - Inner Sheath HFFR
 - 2. Overall Screen Galvanised Steel Wire Braid
 - Outer Sheath HFFR (IEC 60092-360 SHF1), RAL 6018 - Green
 - Reference Standards IEC 60092-376
 
- Operating Voltage 150/250 (300) V
 - Test Voltage 1.5 kV (a.c) 3.6 kV (d.c)
 - Conductor Resistance IEC/EN 60228
 - Insulation Resistance >5000 M.Ωxkm
 - Temperature Range -40 °C........+90 °C
 - Flame Retardancy IEC/EN 60332-1-2, IEC/EN 60332-3-22 (CAT A)
 - Fire Resistance IEC 60331-21
 - Smoke Density IEC/EN 61034-1+2
 - Amount of Halogen Acid Gas IEC/EN 60754-1
 - Corrosive Gases Measurement IEC/EN 60754-2
 - Min. Bending Radius (Fixed) 8 x Cable Diameter