ÜRÜNLER
- Yangına Dayanıklı Kablolar
HBH-K
These indoor tinned telephone cables are used in the subscriber and switchboard system. These cables have halogen-free and flame retardant insulation and sheath.
- Conductor Solid Tinned Copper (IEC/EN 60228)
- Insulation HFFR (EN 50290-2-26)
- Core Colors TSE K 116, IEC 60189-2
- Lay-up Pairs and bundles (each bundle contains of 10 pairs and identified by colored spiral tape)
- Drain Core Insulated Solid Annealed Copper (white color with red ring color)
- Separator PET Foil
- Outer Sheath HFFR (EN 50290-2-27), RAL 7032 - Grey
- Reference Standards TSE K 116, IEC 60189-2
- Operating Voltage 250 V
- Test Voltage 1000 V
- Conductor Resistance ≤97.8 Ω/km
- Insulation Resistance >100 M.Ωxkm
- Mutual Capacitance <120 nF/km
- Capacitance Unbalance (800 Hz) ≤400 pF/500m
- Temperature Range -30 °C........+70 °C
- Flame Retardancy IEC/EN 60332-1
- Smoke Density IEC/EN 61034-2
- Amount of Halogen Acid Gas IEC/EN 60754-1
- Corrosive Gases Measurement IEC/EN 60754-2
- Min. Bending Radius (Fixed) 8 x Cable Diameter